消防(fang)(fang)水(shui)泵(beng)應(ying)由消防(fang)(fang)水(shui)泵(beng)出(chu)水(shui)干(gan)管(guan)上設置(zhi)的壓力開(kai)關(guan)、高位消防(fang)(fang)水(shui)箱(xiang)出(chu)水(shui)管(guan)上的流量開(kai)關(guan),或報警閥壓力開(kai)關(guan)等開(kai)關(guan)信(xin)號應(ying)能直(zhi)接(jie)自(zi)(zi)動(dong)(dong)啟動(dong)(dong)消防(fang)(fang)水(shui)泵(beng)。消防(fang)(fang)水(shui)泵(beng)控(kong)制柜(ju)(ju)應(ying)采取防(fang)(fang)止被水(shui)淹沒的措施(shi)。在(zai)高溫潮濕環境下,消防(fang)(fang)水(shui)泵(beng)控(kong)制柜(ju)(ju)內應(ying)設置(zhi)自(zi)(zi)動(dong)(dong)防(fang)(fang)潮除濕的裝置(zhi)。消防(fang)(fang)水(shui)泵(beng)控(kong)制柜(ju)(ju)前面(mian)板的明顯部位應(ying)設置(zhi)緊急時打開(kai)柜(ju)(ju)門的裝置(zhi)。消防(fang)(fang)水(shui)泵(beng)應(ying)確保從(cong)接(jie)到(dao)啟泵(beng)信(xin)號到(dao)水(shui)泵(beng)正(zheng)常運轉的自(zi)(zi)動(dong)(dong)啟動(dong)(dong)時間不(bu)應(ying)大于(yu)2min 。
消防(fang)水(shui)(shui)(shui)(shui)泵(beng)(beng)(beng)(beng)控制柜在(zai)平時應(ying)(ying)使(shi)消防(fang)水(shui)(shui)(shui)(shui)泵(beng)(beng)(beng)(beng)處于自動(dong)(dong)(dong)啟(qi)(qi)(qi)泵(beng)(beng)(beng)(beng)狀態。穩壓(ya)泵(beng)(beng)(beng)(beng)應(ying)(ying)由消防(fang)給水(shui)(shui)(shui)(shui)管網或(huo)氣壓(ya)水(shui)(shui)(shui)(shui)罐上設(she)置(zhi)的穩壓(ya)泵(beng)(beng)(beng)(beng)自動(dong)(dong)(dong)啟(qi)(qi)(qi)停(ting)泵(beng)(beng)(beng)(beng)壓(ya)力開關(guan)或(huo)壓(ya)力變(bian)送器控制。消防(fang)水(shui)(shui)(shui)(shui)泵(beng)(beng)(beng)(beng)房應(ying)(ying)設(she)置(zhi)排水(shui)(shui)(shui)(shui)設(she)施,消防(fang)水(shui)(shui)(shui)(shui)泵(beng)(beng)(beng)(beng)的布置(zhi)、基礎和管道震(zhen)隔、吸水(shui)(shui)(shui)(shui)管和集水(shui)(shui)(shui)(shui)坑的設(she)計以及泵(beng)(beng)(beng)(beng)房排水(shui)(shui)(shui)(shui)溝、采(cai)暖、起重、通風均應(ying)(ying)符合(he)消防(fang)規范規定的要求。當消防(fang)給水(shui)(shui)(shui)(shui)分(fen)區供(gong)(gong)水(shui)(shui)(shui)(shui)采(cai)用(yong)轉輸消防(fang)水(shui)(shui)(shui)(shui)泵(beng)(beng)(beng)(beng)時,轉輸泵(beng)(beng)(beng)(beng)宜(yi)在(zai)消防(fang)水(shui)(shui)(shui)(shui)泵(beng)(beng)(beng)(beng)啟(qi)(qi)(qi)動(dong)(dong)(dong)后(hou)(hou)再啟(qi)(qi)(qi)動(dong)(dong)(dong);當消防(fang)給水(shui)(shui)(shui)(shui)分(fen)區供(gong)(gong)水(shui)(shui)(shui)(shui)采(cai)用(yong)串聯消防(fang)水(shui)(shui)(shui)(shui)泵(beng)(beng)(beng)(beng)時,上區消防(fang)水(shui)(shui)(shui)(shui)泵(beng)(beng)(beng)(beng)宜(yi)在(zai)下區消防(fang)水(shui)(shui)(shui)(shui)泵(beng)(beng)(beng)(beng)啟(qi)(qi)(qi)動(dong)(dong)(dong)后(hou)(hou)再啟(qi)(qi)(qi)動(dong)(dong)(dong)。
當采用(yong)柴(chai)(chai)油機消防水(shui)泵(beng)(beng)時宜設(she)(she)(she)(she)置(zhi)獨(du)立消防水(shui)泵(beng)(beng)房(fang),并應設(she)(she)(she)(she)置(zhi)滿足(zu)柴(chai)(chai)油機運行的(de)通風、排煙(yan)和阻火設(she)(she)(she)(she)施。消防水(shui)泵(beng)(beng)房(fang)的(de)設(she)(she)(she)(she)計要求:?在有安靜要求的(de)房(fang)間,對其上、下和毗鄰的(de)房(fang)間內,不得設(she)(she)(she)(she)置(zhi)水(shui)泵(beng)(beng);如在其他房(fang)間設(she)(she)(she)(she)置(zhi)水(shui)泵(beng)(beng)時,應采用(yong)水(shui)泵(beng)(beng)的(de)隔震措施。當自動水(shui)滅(mie)火系(xi)統為開式(shi)系(xi)統,且(qie)設(she)(she)(she)(she)置(zhi)自動啟動確(que)有困難時,經論證后消防水(shui)泵(beng)(beng)可(ke)設(she)(she)(she)(she)置(zhi)在手動啟動狀態,并應確(que)保24h有人工(gong)值(zhi)班。
本(ben)網站(zhan)全力支持關于(yu)《中華人民共和國廣(guang)告法》實施的“極(ji)限化違禁(jin)(jin)詞”相關規定,且(qie)已竭(jie)力規避使用(yong)“違禁(jin)(jin)詞”。故即(ji)日起凡(fan)本(ben)網站(zhan)任意(yi)頁面含(han)有(you)極(ji)限化“違禁(jin)(jin)詞”介紹的文字或圖(tu)片,一律非本(ben)網站(zhan)主觀意(yi)愿并即(ji)刻失效(xiao),不可(ke)用(yong)于(yu)客戶任何行(xing)為(wei)的參考依據。凡(fan)訪(fang)客訪(fang)問(wen)本(ben)網站(zhan),均表示(shi)認同此條約!感謝配合!
您好(hao),歡(huan)迎(ying)蒞(li)臨合肥通鴻(hong),歡(huan)迎(ying)咨詢(xun)...
觸屏版二維碼 |